Show / Hide Table of Contents

Class QueueState

Inheritance
System.Object
InputArgs
ResourceArgs
QueueState
Inherited Members
ResourceArgs.Empty
System.Object.Equals(System.Object)
System.Object.Equals(System.Object, System.Object)
System.Object.GetHashCode()
System.Object.GetType()
System.Object.MemberwiseClone()
System.Object.ReferenceEquals(System.Object, System.Object)
System.Object.ToString()
Namespace: Pulumi.AliCloud.Mns
Assembly: Pulumi.AliCloud.dll
Syntax
public sealed class QueueState : ResourceArgs

Constructors

View Source

QueueState()

Declaration
public QueueState()

Properties

View Source

DelaySeconds

This attribute defines the length of time, in seconds, after which every message sent to the queue is dequeued. Valid value range: 0-604800 seconds, i.e., 0 to 7 days. Default value to 0.

Declaration
public Input<int> DelaySeconds { get; set; }
Property Value
Type Description
Input<System.Int32>
View Source

MaximumMessageSize

This indicates the maximum length, in bytes, of any message body sent to the queue. Valid value range: 1024-65536, i.e., 1K to 64K. Default value to 65536.

Declaration
public Input<int> MaximumMessageSize { get; set; }
Property Value
Type Description
Input<System.Int32>
View Source

MessageRetentionPeriod

Messages are deleted from the queue after a specified length of time, whether they have been activated or not. This attribute defines the viability period, in seconds, for every message in the queue. Valid value range: 60-604800 seconds, i.e., 1 minutes to 7 days. Default value to 345600.

Declaration
public Input<int> MessageRetentionPeriod { get; set; }
Property Value
Type Description
Input<System.Int32>
View Source

Name

Two queues on a single account in the same region cannot have the same name. A queue name must start with an English letter or a digit, and can contain English letters, digits, and hyphens, with the length not exceeding 256 characters .

Declaration
public Input<string> Name { get; set; }
Property Value
Type Description
Input<System.String>
View Source

PollingWaitSeconds

Long polling is measured in seconds. When this attribute is set to 0, long polling is disabled. When it is not set to 0, long polling is enabled and message dequeue requests will be processed only when valid messages are received or when long polling times out. Valid value range: 0-30 seconds. Default value to 0.

Declaration
public Input<int> PollingWaitSeconds { get; set; }
Property Value
Type Description
Input<System.Int32>
View Source

VisibilityTimeout

The VisibilityTimeout attribute of the queue. A dequeued messages will change from active (visible) status to inactive (invisible) status, and this attribute defines the length of time, in seconds, that messages remain invisible. Messages return to active status after the set period. Valid value range: 1-43200 seconds, i.e., 1 seconds to 12 hours. Default value to 30.

Declaration
public Input<int> VisibilityTimeout { get; set; }
Property Value
Type Description
Input<System.Int32>
  • View Source
Back to top Copyright 2016-2020, Pulumi Corporation.